EXPERIMENTAL HEAT TRANSFER RATE ON VERTICAL PIPES OF A SIMPLE WATER HARVESTER
One of the tools that can be used to produce clean water is a water harvester. However, this tool is still very low in water production, so it needs to be investigated to increase its water production. This study examines the heat transfer rate from the air to the outer walls of pipes of an evaporator used in the simple air-water harvester. The pipe lengths that varied were 20cm, 40cm and 60cm which were arranged vertically with 138 pipes. The corresponding heat transfer areas were 0.2008m2, 0.3534m2 and 0.5039m2. The results showed that the highest freshwater mass was 308g/7 hours found at the heat transfer area of 0.3534m2, while the highest total heat transfer rate obtained was 59.6W. This study could be used as a reference to design an evaporator of a simple air-water harvester.
air-water harvester, heat transfer area, water mass.
Received: February 2, 2023; Accepted: March 28, 2023; Published: May 18, 2023
How to cite this article: Mirmanto Mirmanto and Ahmad Dwi Aji Pangestu, Experimental heat transfer rate on vertical pipes of a simple water harvester, JP Journal of Heat and Mass Transfer 33 (2023), 41-50. http://dx.doi.org/10.17654/0973576323022
This Open Access Article is Licensed under Creative Commons Attribution 4.0 International License
References:
[1] M. Mirmanto, S. Syahrul, A. T. Wijayanta, A. Mulyanto and L. A. Winata, Effect of evaporator numbers on water production of a free convection air-water harvester, Case Studies in Thermal Engineering 72 (2021), 101253.https://doi.org/10.1016/j.csite.2021.101253.[2] Y. V. Damanik, Pengaruh kecepatan putaran kipas terhadap performansi mesin destilasi air dari udara menggunakan siklus kompresi uap, Thesis, Faculty of Science and Technology, University of Sanata Dharma, Yogyakarta, 2018.[3] Y. W. T. Atmoko, Karakteristik mesin penghasil air dari udara menggunakan mesin siklus kompresi uap dengan tambahan kipas pemadat udara berkecepatan putaran kipas 300 rpm and 350 rpm, Thesis, Mechanical Engineering Department, University of Sanata Dharma, Yogyakarta, 2018.[4] L. A. Winata, Pengaruh jumlah evaporator vertikal terhadap air yang diembunkan dari udara, Mechanical Engineering Department, Engineering Faculty, the University of Mataram, Mataram, 2021.[5] A. Azari, Pengaruh diameter pipa evaporator terhadap massa air yang dihasilkan dengan sistem kompresi uap, Mechanical Engineering Department, Faculty of Engineering, the University of Mataram, Mataram, 2022.[6] A. Fahroni, Pengaruh diameter unit pengembun terhadap massa air yang dihasilkan dari air-water harvester, Thesis, Mechanical Engineering Department, Engineering Faculty, the University of Mataram, Mataram, 2022.[7] http://www.hvac-calculator.net/index.php?v=2.[8] M. Mirmanto, S. Syahrul, M. Wirawan, I. B. Alit and Z. Saputra, Thermoelectric cooler box using a mini pin fin as a heat removal unit: effect of using radiator on coefficient of performance, AIP Conference Proceedings, AIP Publishing LLC, 2021.[9] M. Mirmanto, S. Syahrul, I. W. Joniarta, A. Azari, A. Fahroni, M. Mara, N. Nurpatria and A. T. Wijayanta, Performance of a simple custom air-water harvester using several pipe diameters as the condensation unit, Proceedings of the First Mandalika International Multi-Conference on Science and Engineering, MIMSE (Mechanical and Electrical) (MIMSE-M-E-I-2022), 2022, pp. 102-112.